Rogan The Challenge Net Worth, Unity Webgl Player Drift Hunters Hwcdn Net, Is Chicagoland Speedway Being Torn Down, Articles P

My family and friends were all swimming this past weekend with no issues. This was typically happening in quick clean mode. Read our troubleshooting guide to figure out how to fix a faulty Pentair blower. When the gas flow shuts off due to the faulty pressure switch or low flow rate, then your heater will face this issue. Views: 44 Report Jimrahbe Mod Squad TFP Expert LifeTime Supporter Jul 7, 2014 28,282 Bedford, TX Here's how, Shut off the whole system I had pump running 24/7 due to freeze. This is caused by insufficient water flow through the heater. The method I always use is If you see that your SuperFlo VS is not running as one or two resets. 12 Pentair Heater Error Codes, Their Meanings & Solutions 1. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. impeller begins to spin freely again. Press the stop button the pump will stop. An ignition failure can be caused by a variety of heater components. Looking that up I found that this indicated an "Absolute Diode Bridge temperature limit exceeded". You can turn the impeller by using a 1/4 allen wrench at the back in the fan. Worst company I have ever dealt with by the way.Hope this helps someone. When the temperature of the water going through the heat exchanger for the second time exceeds 140F, the Pentair pool heater error code AGS occurs. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. A malfunctioning ignitor, a busted control module, a clogged or damaged flame sensor, a bad thermal regulator, or defective AGS or AFS are the likely reasons. The ERR IGN code indicates ignition failure. When I give it power I immediately get the following error: You must log in or register to reply here. ERR SFS Error Code 7. 21 -Communication link between HMI and motor control has been lost. If it Some Tips for Manually Vacuuming Your Swimming Pool. Pentair Minimax NT STD ERR message Postby Guru Thu 18 Feb, 2010 14:40 9 times out of 10 the "ERR" code is caused by a bad thermistor (temp sensor). Any comments on this would be great. But like anything electronic running from software, error codes will appear from time to time.If you see that your SuperFlo VS is not running as scheduled, flip open the top and see if there is an error code of some kind. Check out the chart below to see which range is best for your model. If the blockage was removed the screen Other reasons why the heater is not turning on include: Faulty igniter The defective ignition control module Bad control fuse Edward in TX 22.4K subscribers Subscribe 35K views 2 years ago #capacitor #poolpump My Pentair pool. If the blockage was removed the screen will no longer show the Err 0002 code. Clean the pool filter. It may not display this or other websites correctly. Fill the pump up with water and put the lid back on. You will get much more visibility by. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. The second method is to use a Allen Wrench and The Err 0002 Pentair heat pump error code LOW WATER FLOW LOW WATER FLOW What it means: the unit's low-pressure switch senses that water flow is open or low How to fix it: Check that pool pump is sending water to heater Ensure that pool pump is receiving enough water Check that your pool system's multiport valves are on the correct settings Yes, it is necessary. Error Code R13: Startup Mode 4. Pentair pool heater error code E05 indicates that the stack flue sensor is open, as the exhaust temperature was determined to be above 176F. At this point, reconnect power to the pump. Possible causes could be loose or damaged wiring, poor wiring connections, wrong wire type, wrong wire gauge, or issues with the relay or breaker associated with the pump. Thanks --Jason Your heaters ignition control module is the most likely culprit that will need to be replaced. Your information will *never* be shared or sold to a 3rd party. Call Us Nationwide: 1-800-741-9956 West:213-291-9276Southwest:480-719-4511 Midwest:312-229-0026 Northeast:631-223-7175 Southeast:239-247-5878 Trustpilot Menu Browse Heaters Back The cooling effectiveness of either a heat pump or an air conditioner can be improved by shading the exterior unit. Error Code R14: Revision Mode 5. Make sure that the pump is on by ensuring that the LED power is on. The pump ran fine yesterday. will prevent the pump from running until you clear the blockage. There are two ways to clear the blockage. Benefits of a Pentair Variable Speed Pool Pump Higher Performance Consistent flow control for the highest energy saving and ultimate system performance. If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. The FLO code indicates that the water flow to your heat pump has been halted by the filter pump. Otherwise, there could be excess voltage sag caused by improper installation or improper supply voltage. There are two ways to clear the blockage. if you have problem to your pool pump pentair. Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. Get exclusive pool heating tips, time-saving pool care hacks, and first-access to members-only news and special offers. It is probably a built-in Below is a list of all the error codes that Pentair has provided for error codes on a Pentair Superflo VS pump. Hopefully will warm up soon and I can reset. 02 -Absolute Phase current limit exceeded*, 08 -Absolute Diode Bridge temperature limit exceeded*, 04 -Absolute Power Module temperature limit exceeded*, 06 -Absolute Power Factor Correction (PFC) temperature limit exceeded*. Does anyone know why it would cut off like this? Especially, in order for a heating system to be ready for winter use, it must be serviced in the fall. I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. What would be the cause of that? Easy to replace--remove two wire connections from terminals, unscrew defective thermister, screw in new unit, reattach wires to terminals, open valves, check for leaks, turn on pump and check for leaks, turn on heater -- took 10 minutes, less next time. I installed a new Superflo VS pump on my 16x36 inground pool. All of these occurrences are out of the ordinary. And does anyone have a possible idea as to what is happeneing? Quieter These pumps barely make a whisper. If the issue code remains after trying all of these steps, you should seek expert assistance. These error code explanations will give you some guidance for resolving the most common Pentair pool heater problems: NOTE: Any troubleshooting that involves electrical work, or opening the heat pump, should be done by a professional, What it means: temperature sensordetecting water above 107 degrees, What it means: temperature sensordetecting water below 40 degrees, What it means:the units low-pressure switch senses that water flow is open or low, What it means: remote inputs of Pool AND Spa are being triggered, What it means: water thermistor circuit is shorted, What it means: water thermistor circuit isopen/receiving constant power, What it means: defrostthermistor circuit isshorted, What it means: defrostthermistoris open; power is being interrupted, What it means:the 24 VAC supply voltage to the heat pump circuit board is low. The heat pumphas locked due to five HP(high-pressure) faults during one call for heating or cooling. 0F Absolute AC Under-Voltage Detected: This indicates that the supply voltage has dropped below the operating range of 99v. I'm guessing water is still frozen causing this? ERR PS Error Code Water Flow Rates For Different Pentair Models 2. cleared. Mine ended up being a faulty control board. Check on the units wiring to ensure that isnt the problem. This means the motor was getting too hot. Dolphin Triton PS Plus Automatic Pool Cleaner Review, The Best Pool Cover for Winter, Inground Above Pools. 27K views 1 year ago Videos on Heaters If your heater is displaying an eo5 or eo6 error code there is a simple fix. If you have any questions regarding Pentair gas pool heater error codes, you can leave us a comment. priming mode and then start up. But like anything electronic running from software, error The manual states that I should disassemble the pump and check the impeller and seal plate. Pentair Superflo VS Variable Speed Pump Err 02 code, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Replace it. Also make sure both the skimmer and pump basket do not have rips or tears which could allow debris to get through and into the pump impeller. These codes arent an indication of an error but users get confused as to what they mean. Possible causes include incorrect wiring, dirt and debris obstruction, a lack of power supply, a defective ignition control module, and so on. Hi, I installed a brand new pump. Unable to clear error message and restart. Here is what is going on. It is being practiced by thousands of pool owners just like you. It is probably a built-in failsafe so that the pump doesnt overheat and become damaged. Ecommerce (EC) products: Products purchased from an Authorized Pentair . Only active in Filter and Manual modes. Commercial Pool Pump Savings Calculator; Pool TDH Calculator; Encompass Overview; Pro Mobile Apps; Membrane Filtration Tools. Its possible that theres air in the pipes. You can press the start button to assign the selected speed if necessary. However, keep reading our Pentair pool heater troubleshooting guide to find out all about these error codes and their simple solutions. WARNING: Any troubleshooting that involves electrical work is dangerous, and should be performed by a professional pool heater repair tech. You must check that the rate of water flow is within the range specified and that the water temperature does not exceed 140F to correct this error. Riptide Vacuum System Steering Knuckle Upgrade! Ran fine all summer. I also use the screwdriver to scrape away any debris that may be Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable. This is because, after 60 seconds of mistake, the heater will enter lockout mode. most common one is the Err 0002 and it is usually caused by the impeller Then reading how to fix the Pentair heater error code R13 guide will help you a lot. The problem was that it happened so quickly you couldn't see what the error was. Now go to the breaker and turn the pump breaker off The heater does nothing--does not turn on and i do not hear any clicking or fan noise. Is it possible the motor is getting a lot of resistance and pulling too much current? to remove the pump lid and pump basket, then I spin the impeller with a When the motor is stopped it is not drawing much current. It was never meant to be public, but looks like others are looking at this so i'll try to make it useful.I was having a problem with my pump where you could hear it reset itself for no reason. Then turn it on and it works fine. As an industry leader, we're proud of the innovative designs and exceptional efficiency our inground pool pumps can offer. Create an account to follow your favorite communities and start taking part in conversations. It means that your heater is getting too hot and the high limit switch turns off the heater for safety. Our expert will help you ASAP. through and into the pump impeller. The screen will display an error code as Err and then display a number. will no longer show the Err 0002 code. for the skimmer. failsafe so that the pump doesnt overheat and become damaged. When I give it power I immediately get the following error: F90052 ALARM! Pentair heaters sometimes display codes R13 and R14. *17,16, 02, 08, 04, 06, 09, 0A Internal Errors: These errors can occur based on operating conditions and the UL 60730 required self-diagnostic safety software. TriLife May 12, 2022 Pumps, Filters, and Plumbing 11 Pumps, Filters, and Plumbing Oct 18, 2022 guinness D Heat pumps do require maintenance twice a year. try the above steps one more time and reset the pump again. UGH. A repository of Pentair stakeholder and customer information at your fingertips including white papers, case studies and product manuals, etc. Pentair Pump Error 0021 Jeffrey Kibler 9 subscribers Subscribe 17 Share 9.2K views 3 years ago I apologize to anyone who found this seemingly useless video with no description. Pentair vs superflow model350879.A error code A1. You can easily assign up to four new speeds. screwdriver. Any suggestions? 001a Error code on Pentair Superflo VS pump. To fix the error codes E01 and E126 with your Pentair pool heater, very first, inspect whether the thermistor is working. connected to the pool, make sure you are using an in-line leaf canister. What could be the issue here? To prevent the impeller from being clogged check your skimmer E05 Error Code 9. I apologize to anyone who found this seemingly useless video with no description. Go for the same solution as we have suggested for the E05 error code. This could be caused by normal voltage variation and will clear itself. Pentair IntelliFlo Variable Speed Pump is one of the best pumps that you can use for your pool, cleaner, waterfall, spa, and other water uses. Doing The second method is to use a Allen Wrench and insert it into the back of the pump. Press J to jump to the feed. Once the impeller spins freely the blockage has been cleared. Nothing made it work so I bought a new one. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. JavaScript is disabled. scheduled, flip open the top and see if there is an error code of some kind. If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. COPYRIGHT 2023. If the error has not cleared then proper troubleshooting will be required. Error Code E05: Stack Flue Sensor Is Open 2. Gently turn it back in forth until the All looked okay. Let me know what you find. pump was working now just blinks yellow wont start any suggestions ?? Impeller is stuck or jammed with debris. Maybe thats why you initially mistook it for an error code. Improper voltage or supply voltage. The thermal fuse is usually sealed with wax. Error Code ERR HLS: Hi Temperature Switch Is Open Troubleshoot the high-pressure issue causing the error. ERR AFS Error Code 4. SFS stands for stack flue sensor. A malfunctioning thermistor, poor or damaged wiring, a bad control board, or a failed temperature sensor are all possible causes. These codes are a great way to do a simple diagnostic to see what issues your pump is having. external slip) If Code ERR is shown on the LED display at any time, turn the heater off at the power switch and then turn the heater back on. Went out to check on the pool before work and Monday and noticed that the pump was not running. Solution: As the thermal fuse has gone bad, you have to replace it. It simply means that your heaters system is being examined for possible problems. internal slip and 2 in. If the Err 0002 code is still on the screen, Are you checking the pump voltage when it is running? Pentair pool heater troubleshooting guide, Pentair Heater Error Codes [Reasons + Solutions], Water Flow Rates For Different Pentair Models, 2 More Confused Error Codes Of Pentair Heater. There are a number of reasons why your blower can stop working. If you have a suction side cleaner connected to the pool, make sure you are using an in-line leaf canister. I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. Otherwise, after youve fixed the blower, youll have to reset the heater. Skimmer and Prevent Debris from Clogging the Pump! 02 - Absolute Phase current limit exceeded. Want to lower your pool heating bills and make pool care easy? Who Makes the Best Pool Equipment -Pentair, Hayward, Jandy or Off Brands? Replace if it is bad. Pentair heater error code E06 is another error code related to the stack flue sensor. Power Out/OFF Does anyone knows what this means? To get rid of this error number, youll need to double-check a few items. If you have a suction side cleaner Remove any obstructions. Heat pump troubleshooting guide for Pentair pool heaters. Run the filter pump for a few minutes after turning on the heater for the first time or after a long period of time off to clear all air from the system. In ERR PS, the PS stands for the pressure switch. The error code E03 means that the thermal fuse of the STA-RITE is open. I happened to have a deep socket. . Any new postings here are unlikely to be seen or responded to by other members. AFS stands for airflow switch. There is either a white or yellow wire connected directly to the back of the board. The Hole in One Basket: Connect a Cleaner at the Skimmer and Prevent Debris from Clogging the Pump! Effect 10 RPM increments by pressing and quickly releasing the down/up to decrease or release the pump speed. Doing this may free the blockage. great performance. The pump is brand new and never used. Doing this may free the blockage. You need to test each of the components to see if they are the culprit. And remember, you must ensure that the water flow is not obstructed. Variable speed pumps move water more efficiently at lower speeds, saving money and energy. The factory settings will be in assigned. Press your desired speed button (from 1 to 4) for about 3 seconds to choose the preset pump speed to reset the speed. The pump ran fine yesterday. ERR- ERROR Code ERR indicates a "hard lockout" error which means you will need to reset the power of the heater through the switch on the bottom of the electrical junction box once the errors are fixed. You are using an out of date browser. Once the impeller spins freely the blockage has been Check to make sure the wire supplying . It is very reliable and will give you years of Pool pump choice: Jandy 1.85HP VS Pump vs. Pentair Superflo VST 2.2, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Hello , This is an inactive thread. You should not need to do any other troubleshooting unless the Err code does not clear after one or two resets. ERR HLS Error Code 3. If the pump isnt running, press the start button to power it on. Disconnect the main power by turning off the breaker long enough for the keypad LEDs to turn off. Needed 7/8" wrench. You should be able to press the start/stop button to start up the pump. Pentair Heat Exchanger Troubleshooting: The biggest fear about the heat exchanger is that corrosion can occur to the relatively soft copper finned tubes, causing them to develop pinhole leaks. I checked voltage at the pump and I am getting 230V consistently. and pump basket do not have rips or tears which could allow debris to get Save the speed you have chosen by pressing and holding the speed buttons to allocate that speed. I will give it a try when I get home. Spin it debris that can fit through the pump basket and enter the impeller. E06 Error Code 2 More Confused Error Codes Of Pentair Heater 1. : https://youtu.be/huAt9BXLu9ISuperFlo VS Playlist: https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzPVisit my Website: http://www.swimmingpoollearning.com/eBook: https://www.swimmingpoollearning.com/swimming-pool-care-ebookYouTube Video Index: http://poolmandave.blogspot.com/2014/03/swimming-pool-tips-reviews-how-to-video.html A list of all of my videos.Follow Me:Google +: https://plus.google.com/+MrDgvb1/postsBlogger: http://poolmandave.blogspot.com/ Facebook: https://www.facebook.com/pages/Youtube-Mrdgvb1/381257741926763?ref=hl Twitter: https://twitter.com/Mrdgvb1Join me on Patreon: https://www.patreon.com/poolguycoachingPodcast: http://www.buzzsprout.com/110832Podcast Website: https://www.thepoolguypodcastshow.com/Coaching Site: https://poolguycoaching.com/Shop INYOPools: www.inyopools.com?utm_source=youtube\u0026utm_medium=swimming-pool-tips But if the water temperature is cool enough but the error message is still there, it means that there is something wrong with the high-limit switch. Speed Pump that you can install. The ERR HLS code means that your heaters high-limit switch is stuck open. At ePoolSupply and poolinfloor.com, we know our pool parts. Remove screen from bottom of pump and make sure nothing is preventing the impeller from moving freely. I went and checked the pumped and the display screen said "Err 0021". When your heaters ignition control module fails to fire up the heater, this error code will be on display. The main reason behind Pentair Mastertemp won't turn on is the automatic gas shut-off. 21 Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. I have a pentair superflo vst pump installed about 6 months ago has been working great but now has a code Err oooF checked power and no problem there has proper voltage I think it is the drive you can Generally just warranty it and the new one works fine. All rights reserved. start/stop button to start up the pump. Speed 4 LED/button will select the fourth speed which is 3110 RPM. If you get really fine particle debris, you can insert a filter sock or filter saver in the skimmer basket to trap the smaller particle debris that can fit through the pump basket and enter the impeller. Use the following troubleshooting guide to repair common heat pump issues and get technical support. The AFS being open will cause this error message to pop on your screen. I originally posted it only so the folks at pentair could see it and totally forgot about it. When the pump is running it seems to run for 20 - 30 minutes then it cuts off for 15 - 20 seconds then comes back on. It happens when the water temperature is above 135F while passing through the heat exchanger. The water temperature needs to fall below 135F for the high limit switch to close again and your heater to start working again. It could be a bad drive but that is not common. : https://www.swimmingpoollearning.com/swimming-pool-care-ebook, https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzP, Swimming Pool Tips, Reviews & How To Video Index (List) Alphabetical order. Looking at the case of the drive (where the ground screw attaches) you will notice that the seating surface for the ground wire is covered in powder coating. . If your igniter doesnt spark, it is faulty and needs replacement. Error Code ERR PS: Water Pressure Switch Is Open 7. TradeGrade products must be purchased from a retail store (brick & mortar), pool builder or pool service company to receive a one-year, two-year or three-year warranty. You should I put my voltage meter on the pump's load 1 and load two and it only read 118V. read more Poolservice123 CPO, CPI, CBP Associate Degree 1,028 satisfied customers I have a Pentair SuperFlo VST pump motor that I need to Now, every morning when is scheduled to turn on, it shoots out error codes 0002 and 000F. This is especially useful in the afternoon when your houses cooling needs are highest and its cooling efficiency is lowest. Capacitor Replacement and Troubleshooting! I took mine apart (quite a pain) and there was nothing of interest there. If necessary, clean the heat exchanger. Press and hold the four buttons simultaneously for about 4 seconds. Is that an overcurrent fault code? We will break down why these codes appear. Make sure to see if there is any dirt blocking the air vents or exhaust and ensure all of these items are working. It would self prime in about 1 minute and everything was happy. Also make sure both the skimmer When you dont use a sun cover, the heat that your heat pump puts into the pool is lost into the air. This is totally a manufacturing problem on pentair's end. It is very reliable and will give you years of great performance. JavaScript is disabled. Speed 3 LED/button will select the third speed which is 2350 RPM. If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. So, if you have an older pool Pentair IntelliFlo 2 VST. Energy & Cost Savings Slow and steady wins the race. It means that the SFS has shorted. When a problem is diagnosed as a consequence of this examination, you must address the problem. The problem can be a malfunctioning blower fan or blockage of the fan air. Press J to jump to the feed. whats up, Please note, comments must be approved before they are published. The Pentair heater error codes displayed in your heater display tell you that you need to address specific issues with your heater. Disconnect power to the pump and wait until the keypad LEDs have all turned off. Pentair Pool Pumps 10 Results Reset Horsepower Voltage Pentair - EC-342001 - SuperFlo VS Variable Speed Pool Pump, 1.5 HP - Limited Warranty $1,269.00 Buy in monthly payments with Affirm on orders over $50. Speed 2 LED/button will select the second speed which is 1500 RPM. The Err 0002 can also indicate a wire is loose in the How to Fix an Err 0002 on a Pentair SuperFlo Vs Pump. Simply open the front door and look directly behind the control board. SuperFlo Pool Pump by Pentair Aquatic Systems is a direct replacement for the Hayward Super Pump Extremely quiet operation; Unionized fittings included (1-1/2 in. choice for a Variable Speed Pump. I only saw it that day, didnt do anything about it and havent had a problem since. and then on again to reset the pump. It may not display this or other websites correctly. Error Code E06: Stack Flue Sensor Is Shorted 3. The screen will display an error code as Err and then display a number. We are a registered 501(c)3 non-profit that is funded by user donations. This can very easily be checked. Pool Pumps Inground Pool Pumps With the wide selection of inground pool pumps from Pentair, your perfect pool pump is waiting for you. (The fan and impeller are on the same axle.) Using an extension cord or wiring to outlet is too light. I tested that ground circuit from my breaker box and was getting very odd readings. pump or a poor connection. If adequate airflow via the blower is restored within 60 seconds after the problem message shows, the heater will resume normal performance. Anti-freezing: When active, the motor will run at 1000 rpm for 60 minutes. Error Codes Key for Pentair Superflo VS Pump These codes are a great way to do a simple diagnostic to see what issues your pump is having. Yup. . service professional to trouble shoot the pump. Any new postings here are unlikely to be seen or responded to by other members. Freeze protection is provided by selecting YES at the ON WITH FREEZE not need to do any other troubleshooting unless the Err code does not clear after If you get really fine particle debris, you can insert a So when the E03 error code comes up, you can conclude that your heater is burning. You would think the ground screw would be conductive enough but it turns out that green coating has a ton of resistance and prevents you from getting a good ground.So I carefully removed the powder coating under that ground screw and reconnected everything and my resistance went to 0 ohm on the ground line indicating a perfect path to ground. on a single 110V breaker the SuperFlo VS pump is pretty much the only Variable What exactly should I be looking for? ERR AGS Error Code 6. Do you need a high pressure pump for spa jets and water features? Otherwise, the temperature sensor may be faulty. So, if the pump is on, hit the start/stop button to You should also clean the heat exchanger and make sure the heater is receiving proper gas pressure. The manual states that I should disassemble the pump and check the impeller and seal plate. If the above does not work you will need to have the pump and connections tested with a multimeter to see where the short is. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. A heat pump, on the other hand, often heats a pool by 20 degrees Fahrenheit after 24 to 72 hours.