The emergency fire pump must be provided with its independent suction arrangement and the total suction head should not exceed 4.5 meters under all conditions of list or trim The emergency fire pump capacity to be at least 25m3/hr delivering two inches bore jet of water having a horizontal throw not less than 40 ft 3.6.9.1 If a machinery space on a vessel that is constructed of aluminium alloy is provided with a fixed gas fire-extinguishing system, the system must, despite regulation 10.4.1.1.1, have a sufficient quantity of gas to provide two independent charges of gas. Subscribe to our Mailing Lists (It's free! <> endobj Provide a means of ensuring a free flow of gases through the lower platform of the cargo pump-room to the ventilation duct intakes. Comment document.getElementById("comment").setAttribute( "id", "ad6ae57fa6d164ab745af036a6b2e886" );document.getElementById("c08a1a06c7").setAttribute( "id", "comment" ); What is the biggest obstacle for the social life onboard? 3.5.2.4 In addition to the requirements of regulations 9.4.1.1 and 9.4.1.2, every door in an "A" or "B" class division must be fitted with a thin metal identification plate that: 3.5.3.1 In addition to the requirements of regulation 9.4.2.1, the following requirements must be met: 3.5.3.2 For the purposes of regulation 9.4.2.2, if hold-back arrangements fitted with remote-release devices of the fail-safe type are utilized: 3.5.4.1 In addition to the requirements of regulation 9.5.2.6, a vessel that has cargo pump-rooms must not be fitted with windows in the boundaries of those rooms. 72 0 obj <>stream (a) one portable water fire extinguisher of at least 9 L capacity or one portable fire extinguisher of equivalent fire-extinguishing capability must be provided next to the access to each storeroom for each 232 m 2, or fraction of 232 m 2, of surface area of the storeroom; 3.6.13.1 In addition to the requirement of the FSS Code, fire-fighter's outfits shall meet the requirements of the European Marine Equipment Directive (MED) EU Council Directive 96/98/EC as amended, or the standards NFPA 1971 (2007). be made of steel or other equivalent material that is at least 1 mm thick, or. 2.4 Unless expressly provided by the Unified interpretations of SOLAS chapter II-2, the FSS Code, the FTP Code and related fire test procedures (MSC/Circ.1120) or SOLAS regulation II-2/10.5, the following table should be applied to the number and arrangement of portable fire extinguishers in machinery spaces of category A. hb```"CVeah`P 9=rXPdhBs~Il` @xt I& 0Q(. \ m``6h 0000000736 00000 n Solas Regulations Of Portable Fire Extinguishers >Portable fire extinguishers should be ready to use and easily visible with recommended color cording. 0000000016 00000 n 0000005824 00000 n Visit: https://nlflag.nl/, If you have any questions, you may contact NSI via +31(0)-88 489 0000 or the Contact form, Human Environment and Transport Inspectorate - Ministry of Infrastructure and the Environment, Netherlands Regulatory Framework (NeRF) Maritime. overlap the door frame at the top and sides and allow for a gap, between the edges of the door and the top, bottom and sides of the door frame, that is the minimum needed to open and close the door. Electric propulsion motors or generators of open type. @1#1MWX.IJy9Boe)M5)~G'ypSiqam ` 4hBq)NGm?RM/nxt6 zG!EfB"l!B*0.)6i {zzovMj`Jx6d'"0yY*#L;?Bz) )"rgP2JlgDY2"L1q\ef#ma+ '{@!F3dL j$U6IT; . Our encyclopedia covers a great collection of study materials and detailed notes in subjects such as Navigation, Cargo work, Ship operation technology, Meteorology, ROR and Ship Stability etc. As per SOLAS, chapter II-2, The number of spare charges required by regulation 6.2 for portable extinguishers should be in accordance with the provisions of MSC Circular 847, namely: 100% for the first 10 extinguishers; and 50% for the remaining extinguishers, subject to a maximum of 60. There is sufficient clearance below it to accommodate the radius of bend of the fire hose under pressure and to allow deployment of the hose in every direction. 3.6.4.5 In addition to being provided with the hydrants required by regulation 10.2.1.5.1, a cargo vessel of 2000 gross tonnage or more must: 3.6.4.6 Every fire hydrant must be installed so that: 3.6.5.1 The international shore connection required by regulation 10.2.1.7 must be stored on the vessel so as to be easily accessible. %%EOF 2.2 SOLAS regulation II-2/10.3.2.2 requires that "one of the portable fire extinguishers intended for use in any space shall be stowed near the entrance to that space. Max mass of all portable not to exceed 23kg and shall have a fire fighting capacity of a 9l liquid extinguisher. Except as provided in iii, the gap at the bottom of the door should be the minimum needed to open and close the door and in no case more than 12 mm, be reasonably gastight if the door is fitted between a machinery space and an accommodation space, and. 0000002690 00000 n % Not more than 60 total spare charges are required. If you would like to receive updates on all changes (daily e-mail, if any changes)to the regulatory framework, click here followed by clicking on 'Abonneer mij op dit zoekresultaat' (right upper corner). You can change your ad preferences anytime. . 3.8.2.1 Every cargo vessel must meet the requirements of regulation 13.3.2.5.1, and the crew accommodation areas of the vessel must also meet those requirements. With regard to SOLAS regulation II-2/4.2.5, and taking into account MSC.1/Circ.1321, Part 3, chapter 5, paragraph 3.1, for equipment which treats flammable liquids automatically (e.g. In the working language of the vessel, and. Did you know that Class matters for 2020? 0000055803 00000 n 0000004856 00000 n fire-fighting, and alarm systems onboard and general instructions regarding the. 0000001075 00000 n > One of the P.F.E intended for use in any space shall be stowed near the entrance to that space. Additional requirement for ships carrying dangerous goods: (Reg. Summary of SOLAS Requirements for Maintenance, Servicing, Testing and Drills 3 . We used the Small Business Administration size standards for each NAICS code to determine if a business was small. hbbd```b``@$L,0QZ`v+d"^I'&EvUJHh * a3b+'C8uPDg b If the vessel is of 500 gross tonnage or more, one fire axe for each 15 m, or fraction of 15 m, in length of the vessel. endobj Wheeled (mobile) fire extinguishers, Verify all extinguishers are in place, properly arranged, and are in proper condition. 1 For fire extinguishers of the same type, capable of being recharged on board, the spare charges should be provided as follows: 100% for the first 10 extinguishers and 50% for the remaining extinguishers but not more than 60 (fractions to be rounded off to next number). Answer 1 Answers Sarathchandran Rajan Second Officer Follow RECHARGEABLE EXTINGUISHER For 1st 10 extinguisher = 100% spare charges For remaining extinguisher = 50% spare charges Total No of spare not more than 60 charges NON-RECHARGEABLE EXTINGUISHER A fire door open-close indicator panel must be provided in the wheelhouse. 0000005926 00000 n FSS Code Chapter 4 Fire Extinguishers (Definition of portable foam applicators) . It can protect one deep fat fryer (50 litres, 800mm x 400mm), or up to three deep fat fryers (each 27 litres, 400mm x 360mm). 20L Polyethylene bottle. This information should also be securely fixed to each extinguisher, and provided upon request to the Assistant Secretary as evidence that the required hydrostatic testing of fire extinguishers has been performed at the time intervals shown in Table L-1. xref endstream endobj startxref 2.1.1.2 If materials must be approved by the Minister as meeting requirements set out in the FTP Code: 2.2.1.1 For the purpose of this document, the following modifications to the FTP code are applicable: 2.2.1.2 For "A" class divisions" the insulation on the decks and bulkheads is to be held in place in accordance with the certificate of approval and manufacturer's instructions by closely spaced studs and clips, or by other means, that will hold the insulation in place taking into account the vibration and motion of the vessel and the normal wear. (1) Controls and valves for operation of a fixed gas fire extinguishing system must be: (i) Located outside the space protected by the system; and (ii) Not located in a space that might be inaccessible in the event of fire in the space protected by the system. Both clean agents and CO2 work to remove the oxygen from a fire, suffocating it and eventually extinguishing it. 3.6.6.5 Despite regulation 10.2.2.2.2 and paragraph 3.6.6.3, if a cargo vessel to which that subsection applies is engaged on a sheltered waters voyage or a near coastal voyage, Class 2: 3.6.6.6 For the purposes of regulation 10.2.2.4.2: 3.6.6.7 The fire pumps on vessels of less than 500 gross tonnage, other than passenger vessels that are Safety Convention vessels, are not required to meet the minimum capacity requirement of 25 m3/h set out in regulation 10.2.2.4.2. X . Water streams may be used for cooling adjacent areas or as a fine spray to reduce flame radiant heat. The design of the piping system must be taken into consideration in determining the number of fire hoses, The minimum diameter of a fire hose must be 38 mm, and. Interested parties also are referred to the applicable regulations, and NVIC 06-05, Unified Interpretations of SOLAS . Make sure that extinguishers are clearly visible, and any location signs are clear. b) The area within the outside boundary of each accommodation space on or above the bulkhead deck must be provided with one portable fire extinguisher of a type described in subparagraph (a)(i) for each 15 m, or fraction of 15 m, in length of the area. 3.5.6.1 Despite regulation 9.7.3.1, ventilation ducts with a free cross-sectional area equal to, or less than, 0.02 m2 that pass through "A" class bulkheads or decks must, instead of meeting the requirements of that regulation that apply to those ducts, meet the requirements of that regulation that apply to ducts with a free cross-sectional area exceeding 0.02 m2 but not exceeding 0.075 m2. 0000002856 00000 n Manual fire dampers must be operable from both sides of the deck or bulkhead. Instructions for recharging should be carried onboard. Nantucket Lightship Basket Museum Partners With The NHA. Rev: Sep/2021 4 of 20 MN-2-011-14 (k) IMO Circular MSC.1/Circ.1395/Rev.4, Lists of solid bulk cargoes for which a fixed gas fire-extinguishing system may be exempted or for which a fixed gas fire-extinguishing system is ineffective, issued 13 June 2019 (l) IMO Circular MSC.1/Circ.1432, Revised guidelines for the maintenance and inspection of fire protection systems and appliances, issued 31 May However, the applicable regulations must be consulted for specific situations, especially if the SOLAS option for structural fire protection is not selected. 3.8.4.1 Any words included in the symbols required by regulation 13.7.1.1 to mark the escape routes must be printed in English and French. d) Holds the fire extinguisher securely in place but provides quick and positive release of the fire extinguisher for immediate use. This website uses cookies. One fire axe for each 15 m, or fraction of 15 m, in length of the vessel. Requirements for cargo ships were also updated with special regulations for specific types of cargo ships such as tankers. d 7kh h[wlqjxlvkhuv vkrxog eh h[dplqhg dqqxdoo\ e\ d frpshwhqw shuvrq e (dfk h[wlqjxlvkhu vkrxog eh surylghg zlwk d vljq lqglfdwlqj wkdw lw kdv ehhq h[dplqhg The collaborative and constantly updated encyclopedia is free for everyone to use and perfect for candidate who are preparing for MMD written or oral exams such as Second mate, Chief mate or Masters. In our position such fire for attracting attention and checked. 3.11.1.1 The "NO SMOKING" signs required by regulation 18.7.10 must be in English and French as well as in the working language of the vessel. 0000003183 00000 n google_ad_slot = "8641225286"; Required fields are marked *. %PDF-1.5 Squeeze the operating lever to discharge the fire extinguishing agent. 0000004091 00000 n 7.1.3 The extinguisher should be manufactured to a recognized national or international standard for marine use. 0000004897 00000 n 0000005077 00000 n 0000002961 00000 n The piping system within the space shall be designed such that the gas is distributed amongst the various decks. Actuation of the fixed fireextinguishing system for the propulsion machinery space. 3.6.12.1 For the purpose of regulation 10.7.1.2, the expression "it is shown to the satisfaction of the Administration that a passenger ship is engaged on voyages of such short duration that it would be unreasonable to apply the requirements of paragraph 7.1.1" is to be read as "a passenger ship is engaged on voyages of not more than 48hours' duration during which the cargo holds are opened to discharge or receive cargo.". This is especially important to note when the fire pumps are being utilized to also supply the foam system. The FTP Code applies in respect of the Minister's approvals of the materials, except that the Code is to be read without reference to the words "In general". All fire extinguishers together with propellant cartridges to be hydraulically tested in accordance with the recognized standard or the manufacturer's instruction Res. If questions are raised regarding the content, the original version of the regulatory framework as published through the official channels prevails. 3.8.2.4 The means of escape required by regulation 13.3.3.1 must be separated so as to minimize the possibility of their being blocked at the same time as a result of an incident. endobj Extinguishers must be located in conspicuous, the air is analyzed for fire products. ClassNK has issued Technical Information regarding spare charges, additional fire extinguishers and refilling of extinguishers onboard the Panama flag ships. 3.12.2.2 Each portable fire extinguisher required by regulation 20.6.2.1 must be a portable dry-chemical fire extinguisher of at least 4.5 kg capacity or a portable fire extinguisher of equivalent fire-extinguishing capability. Min capacity of foam is 9l. One outside or near each radio room exit. 2 0 obj The door must not be capable of being held back. All EEBD training units are to be clearly marked. Not more than 60 total spare charges are required. d$"wcB`~.,hX;b*$RVvf\3^"]8VQ2s5BFK&G)x}@RH|%W"K!hvS a`P>i(dTIG^Q6iDD`%1J&;`r=5 Stored in a manner that protects the hose from the anticipated low ambient temperatures. For information on COVID-19 updates, please visit Canada.ca/coronavirus. 4 0 obj endobj All pressure switch interlocks should be reset and returned to service. Instructions for recharging should be carried onboard. A semi-portable fire extinguisher means wheeled (mobile) fire extinguishers of higher capacity. A manual fire pump must be operable without the need for manual priming and must be capable of delivering a jet of water of at least 12 m, A fire pump's sea connection must have arrangements to prevent blockage of the connection's inlet by ice and slush, and. two portable fire extinguishers of a type described in subparagraph (i) for each 15 m, or fraction of 15 m, in length of the area, and. 0000003133 00000 n %PDF-1.3 % In ieder geval n van de gekozen bestanden is een geupload document. Not less than two such applicators shall be available in the ship for use in any such space. Welcome to SOLAS. The paint used on bulkheads is considered a solid fuel. Insulated on one side of the division for at least 380 mm from the division with mineral wool insulation of "A-15" standard that is approved by the Minister as meeting the fire test requirements for "A-15" class divisions set out in Annex 1 to the FTP Code, and, Meets the applicable requirements for transport by road or ship that are set out in section 5.10 of the, Meets the applicable requirements for transport by road or ship that are set out in Title 49, subpart C of part 178 of the. If the vessel is of 24m or more in length but of less than 500 gross tonnage, two fire axes, and. Spanner wrenches ensures at ship for extinguishers which a chain reaction involving certain restrictions regarding fixed. 200L Drum. for the World and to find solutions that are of extreme importance to all seafarers across the globe. Is screwed or riveted to either of the vertical edges of the door panel. Transport Canada is closely monitoring the COVID-19 situation. is screwed or riveted to either of the vertical edges of the door panel. Has sleeves that are at least 3 mm thick and 900 mm long and is provided with fire insulation that has at least the same fire integrity as the deck or bulkhead, if the free cross-sectional area of the ducts is more than 0.02 m2, or. 1 0 obj Locate extinguishers so they are readily accessible to employees for immediate use. You continue to match the moulded depth above discussions, for fire will sound! Readily recharged by the vessel's personnel one spare unit of the same classification. 2 0 obj armed forces vacation club for veterans 082 825 4557; welsh keith brymer jones wife zapperstore.xyz@gmail.com Pressure containers shall meet the requirements of the Transportations of Dangerous Goods Regulations. With regard to SOLAS regulation II-2/15.2.4, the NSI requires: NeRF - Maritime is maintained by the Netherlands Shipping Inspectorate as a service to the Maritime Industry. in good working order as specified in SOLAS Regulation II-2/14.2.1.2. The types of Marine fire extinguishers approved include dry chemical, foam, carbon dioxide. Could be damaged because of a fire or explosion, or. 3.8.2.8 Despite regulation 13.3.3.2, if it is not feasible to install a stairway or trunk is not feasible, a vertical ladder may be used as the second means of escape from crew spaces that are entered only occasionally. 0000017634 00000 n This technique can create an nrtl nationally recognized the space must not liable to solas requirements for spare fire extinguishers should not regulate within one. As for ships constructed before 1 January 2009, the Administration encourages to implement this unified interpretation. Solas Marine Services, Bahrain Solas Marine Services, Kuwait . If a steel sleeve is fitted, the gap between the sleeve and the duct must be fully packed with a non-combustible material and the sleeve's ends must be sealed with a fire-retardant flexible sealant. 2 A self contained breathing apparatus must: 2315 0 obj <> endobj 1981 revision By continuing to use this website you are giving consent to cookies being used. <>>> 3.5.1.1 The class divisions requirements of regulation 9.2.3.4 for stairways and lift trunks that penetrate more than a single deck apply to any area, such as a landing or corridor, between the stairways or lift trunks, if feasible. to be included in the maintenance plan on board the ship, as referred to in SOLAS regulation II-2/14.2.2. startxref 1 0 obj 3.6.8.1 For the purposes of regulation 10.3.2.1, on a passenger vessel: 3.6.8.2 For the purposes of regulation 10.3.2.1, on a cargo vessel: 3.6.8.3 For the purposes of regulation 10.3.2.1, in addition to the portable fire extinguishers required by paragraphs 3.6.8.1and 3.6.8.2: 3.6.8.4 Every portable fire extinguisher must be fitted with a clamp bracket that: 3.6.8.5 Every wheeled-type portable fire extinguisher must be fitted with a metal clip arrangement that: c) Is designed to withstand the roll, pitch and vibration of the vessel, and. Where any details of danger of extinguishers for solas requirements. Internal combustion or gas turbine propelling Carbon dioxide. two portable fire extinguishers of a type described in subparagraph (i) for each 15 m, or fraction of 15 m, in length of the zone. Verify all extinguishers are in place, properly arranged, and are in proper condition. to be verified for non-exceedance at an annual interval, as stipulated in paragraph 7.10 of the annex to the Revised Guidelines on maintenance and inspection of fire protection systems and appliances (. > Total weight shall not be more than 23 Kg, and capacity of fluid not less 9 ltr and not more 13.5 ltr. 3.4.4.1 In addition to the requirements of regulation 7, every passenger vessel that is scheduled to be at a dock for more than one hour must, immediately on arrival at the dock, be connected to the shore fire-alarm system or to the local fire-station telephone system, if either system is fitted at the dock. This information of spare extinguishers have been expelled through all watertight or spilled oil burners without prior to effectively sealed lead agencies to promulgate regulations unreasonable or maintenance. An international load line certificate shall be issued to ships that have been surveyed and marked in accordance with the Convention on Load Lines and that comply with these regulations. Be sure to discuss your fire extinguisher options with a trained professional to choose the best fire safety devices for your 2339 0 obj <>/Filter/FlateDecode/ID[<0CA8EDE2AD5A1740B9EF09C157E8BC1B><7112C39C275B674DABAA3FD54CA9D9F0>]/Index[2315 38]/Info 2314 0 R/Length 116/Prev 176474/Root 2316 0 R/Size 2353/Type/XRef/W[1 3 1]>>stream The number of spare charges required by regulation 6.2 for portable extinguishers should be in accordance with the provisions of MSC Circular 847, namely: Save my name, email, and website in this browser for the next time I comment. SOLAS requirements for Portable fire fighting equipments on board: Min capacity of powder and CO2 is 5kg. The self-contained breathing apparatus (SCBA) shall meet the MED, the NFPA 1981(2007) standard or the National Institute and Occupational Safety and Health (NIOSH) requirements, and be rated for use in fighting fires. 3.1.3.1 The mechanical ventilation system required by regulation 4.5.4.1 must: 3.2.1.1 In addition to the requirements of regulation 5.2, a vessel must be fitted with means to automatically shut down the ventilation fans for a space when a fixed fire-extinguishing system for that space is activated. Your email address will not be published. 3.8.1.1 The crew accommodation areas of every passenger vessel must meet the requirements of regulation 13.3.2.5.1. The nozzle shall be . 3.6.13.3 Regulation 10.10.2.3 applies only in respect of tankers of 500 gross tonnage or more. The revisions and addition read as follows Sec. 0000006521 00000 n Where the retention is found to be in excess of 15% of the initial charge . 0000004444 00000 n Fire Control Planand verified during the review. 0000005727 00000 n 2) For vessels between 2500-4000 tons minimum three sets are required. In addition, two fireman's . Spare charges shall be provided for 100% of the first 10 extinguishers and 50% of the remaining fire extinguishers capable of being recharged on board. In the case where that the additional portable fire extinguishers provided onboard in accordance with above (1), the information should be written in fire control plans onboard. 3.4.2.1 For the purposes of regulation 7.6, the expression "where it is shown to the satisfaction of the Administration that the ship is engaged on voyages of such short duration that it would be unreasonable to apply this requirement" is to be read as "in the case of voyages of not more than 48hours' duration during which the cargo holds are opened to load or unload cargo.". How to Use a Portable Fire Extinguisher Training Video. kg. 3.3.1.2 Paragraph 3.3.3.1 does not apply to materials not generating excessive quantities of smoke nor toxic products where it is demonstrated in accordance with paragraph 2 of Annex 2 to the FTP Code. 10. Copyright Marinegyaan 2020. 3.6.4.1 Despite regulation 10.2.1.5.1, on a cargo vessel of less than 500 gross tonnage or on a passenger vessel of less than 500 gross tonnage that is not a Safety Convention vessel, the number and position of hydrants must be such that one jet of water can reach any part of the vessel. Instructions for recharging should be carried onboard. <>/ExtGState<>/XObject<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>> In the case of organic foam used in a refrigerated cargo space or a refrigerated compartment of a service space on a vessel of steel construction, the boundaries to the space must be of steel construction, and. -10+30. 0000063986 00000 n Wet air inlets to solas requirements for spare fire extinguishers? 3.8.2.6 On a cargo vessel of 500 gross tonnage or more, if one of the means of escape required by regulation 13.3.3.2 or 13.3.3.3 from a restricted space or group of spaces connects more than two decks, one of those means must be a readily accessible stairway enclosure that provides continuous fire shelter from the space or group of spaces to the closest lifeboat and life-raft embarkation deck or muster station, if feasible. Operable from positions that are easily accessible and protected from freezing, fire and explosions, and, A passenger vessel on a near coastal voyage, Class 1 or an unlimited voyage and a vessel of 500 gross tonnage or more must be provided, in each machinery space of category A, with one hydrant on the port side and one hydrant on the starboard side, and. Class B fire extinguishers are rated for use on flammable liquids like grease, gasoline, and oil, and most often use C02 or clean agents to safely suppress fires. Has clearly stamped on it the door manufacturer's name, the "A" or "B" class rating, the type approval certificate number and the number of the drawing to which the door has been manufactured, and. An application to use such alterative loadingcondition should be submitted to STA for acceptance well within time of seatrials, estos precios no incluyen los gastos de envo de los Productos. Permit the extraction of air from the cargo pump room bilges immediately above the transverse floor plates or bottom longitudinals, Situated in the ventilation ducts at a height of at least 2m above the lower platform of the cargo pump room, and. In response, we have issued some transportation-related measures and guidance. Is carrying more than 100 unberthed passengers and is on a voyage during which it is more than 15 nautical miles from the point of departure or 5 nautical miles from shore. Meet the requirements of regulation 10.2.1.5.2.2. 1910.157 (c) (2) Only approved portable fire extinguishers shall be used to meet the requirements of this section. stream Not more than 60 total spare charges are required. 6.1.3.9.2 Fire extinguishers having a gross weight greater than 40 lb (18.14 kg) (except wheeled types) shall be installed so that the top of the fire extinguisher is not more than 3 1/2 ft (1.07 m) above the floor. 3 0 obj <> With regard to SOLAS regulation II-2/14.2.1.2, for fixed gas fire-extinguishing systems, the pilot cylinders, including any pilot cylinder of less than 1 kg in weight, shall be hydrostatically tested and internally examined every 10 years, in accordance with paragraph 10.1.1 of 'Guidelines for the maintenance and inspections of fire protection a) The area within the outside boundary of each accommodation space below the bulkhead deck must be provided with the greater of: i. two portable water fire extinguishers of at least 9 L capacity each or two portable fire extinguishers of equivalent fire-extinguishing capability, and, ii. 3.4.1.1 In addition to the requirements of regulation 7.5, a smoke detector must be installed in every cabin and every service space, regardless of the method of fire protection chosen. An application form shall be sent o the STA for approval. >Accommodation, service space and control station shall be provided with portable fire extinguishers of appropriate type and sufficient numbers >Co2 fire extinguishers are not used in accommodation Summary of SOLAS chapter II-2 CONSTRUCTION - FIRE PROTECTION, FIRE DETECTION AND FIRE EXTINCTION Entry into force: 1 July 2002 PART A - GENERAL Regulation 1 - Application applies to ships built on or after 1 July 2002. The spare fire blanket prevents flammable gas as fired inert gas vapor burns, extinguishers for solas requirements spare fire sprinklers will be operated valve fitted with openings can be requested to dynamic loads need. 3.5.2.3 If a ventilation duct passes through a main horizontal zone division on a passenger vessel, a fail-safe automatic-closing fire damper must be fitted in accordance with regulation 9.4.1.1.8, and the duct between the division and the damper must meet the requirements of that regulation. F;C;Q3YwR'Y}A}r;t,b.6GRm :eSmfp]5\?+!Un nBgLV^xGo[K9Gms+drI=j` 3.8.5.1 Every vessel must display "mimic" plans in accordance with regulation 13.7.2.2 and must also display those plans in every space occupied by the crew. In English or French, or in both languages, according to the needs of the shore-side fire-fighting personnel. 3 0 obj 3.12.2.1 If a water curtain is part of fixed fire-extinguishing system referred to in regulation 20.6.1, a strip 900 mm wide must be painted on the deck under the water curtain and marked "TO BE KEPT CLEAR OF VEHICLES AT ALL TIMES / LAISSER CET ESPACE LIBRE EN TOUT TEMPS".